In order to ensure the consistency of the mass-produced film faced plywood with the sample, the film faced plywood supplier shall meet the quality assurance capability requirements specified in this document.
1. Responsibilities of film faced plywood supplier.
The film faced plywood supplier shall specify the responsibilities and interrelationships of various personnel related to quality activities, and the factory shall designate a quality person in charge within the organization, regardless of the member’s responsibilities in other aspects, shall have the following responsibilities and Permissions:
1.) Responsible for establishing a quality system that meets the requirements of this document, and ensuring its implementation and maintenance;
2.) Ensure that the template affixed with the certification mark meets the requirements of the certification standard;
3.) Establish documented procedures to ensure proper storage and use of certification marks;
4.) Establish a documented procedure to ensure that the certification mark will not be affixed to the substandard products or the certified template that has not been confirmed by the certification body after the change of the certified template. film faced plywood supplier The person in charge of quality should be fully competent for his job.
2. Resources of film faced plywood supplier.
The film faced plywood supplier should be equipped with the necessary production equipment and inspection equipment to meet the requirements of stable production conforming to the standards of the formwork; should be equipped with corresponding human resources to ensure that the staff engaged in the quality of the formwork have the necessary capabilities; establish and maintain suitable Template storage and other necessary environments.
3. Documents of film faced plywood supplier.
The film faced plywood supplier shall establish a documented quality plan for film faced plywood or similar.
The quality plan should include:
1.) Template design purpose, implementation process, inspection and regulations on related resources;
2.) The regulations on the management of changes (standards, processes, key materials, etc.) of film faced plywood have been certified;
3.) Regulations governing the use of logos related to film faced plywood.
The film faced plywood design criteria or regulations shall be part of a quality programme and shall not be less demanding than the certification criteria for that film faced plywood.
The factory shall establish and maintain documented procedures to effectively control the documents and information required by this document. These controls should ensure Pre-release and changes should be approved by the licensor to ensure their suitability.
4. Film faced plywood supplier purchasing and incoming inspection.
film faced plywood supplier supplier control.
The film faced plywood supplier shall formulate procedures for the selection, evaluation, and daily management of key raw material suppliers to ensure that the supplier has the ability to ensure that the production raw materials meet the requirements.
The film faced plywood supplier shall keep records of supplier selection evaluation and daily management.
Film faced plywood supplier inspection/verification of raw materials
A film faced plywood supplier shall establish and maintain procedures for the inspection or verification of raw materials provided by the supplier and for periodic confirmation of inspection procedures to ensure that the requirements specified in the certification are met.
The inspection of film faced plywood’s key raw materials can be done by the factory or by the supplier.
When inspected by the supplier, the factory shall make clear requirements for the supplier.
The film faced plywood supplier shall keep the inspection or verification records of key raw materials, the confirmation inspection records and the qualification certificates and relevant inspection data provided by the suppliers.
5. Film faced plywood supplier production process control and process inspection.
1.) The film faced plywood supplier should identify the key production process, and the operators of the key process should have the corresponding ability. If the process does not have documents that cannot guarantee the quality of the template, then the corresponding process documents and work instructions should be formulated to make the process easier. controlled.
2.) Film faced plywood If there are requirements for environmental conditions during the production process, the factory should ensure that the working environment meets the specified requirements.
3.) The film faced plywood supplier shall establish and maintain a maintenance system for the production equipment.
4.) The film faced plywood supplier should inspect/check the template at the appropriate stage of production to ensure that the template and raw materials are consistent with the certified samples.
6. Film faced plywood supplier routine inspection and confirmation inspection.
The film faced plywood supplier shall develop and maintain documented routine inspection and verification inspection procedures to verify that the formwork meets the stated requirements. The inspection procedures shall include inspection engineering, content, methods, judgments, etc., and inspection records shall be kept.
The specific routine inspection and confirmation inspection requirements should meet the requirements of the corresponding film faced plywood certification implementation regulations.
Film faced plywood supplier Routine inspection is a 100% inspection of the formwork on the production line at the final stage of production, usually after inspection, no further processing except for packaging and labelling.
The film faced plywood supplier confirmation inspection is a sampling inspection to verify that the template continues to meet the standard requirements.
7. Film faced plywood supplier inspection equipment.
The equipment used for inspection shall be calibrated and inspected regularly, and shall meet the inspection capability.
The inspection equipment shall have operating procedures, and the inspectors shall be able to use the instruments and equipment accurately according to the requirements of the operating procedures.
1.) Film faced plywood supplier calibration and verification
The inspection equipment used to determine that the film faced plywood produced meets the specified requirements shall be calibrated or verified at the specified cycle.
Calibration or verification shall be traceable to national or international standards.
For self-calibrated instruments and equipment, the calibration method, acceptance criteria and calibration period should be specified.
The calibration status of the equipment should be easily identifiable by users and managers.
Calibration records for the equipment should be kept.
2.) Film faced plywood supplier run check
Film faced plywood supplier Equipment used for routine inspections and confirmation inspections should be subject to operational inspections in addition to routine operational inspections.
When it is found that the results of the operation inspection cannot meet the specified requirements, it shall be able to trace back to the template that has been inspected.
When necessary, these templates should be retested. The measures that the operator can take when the equipment is found to be malfunctioning should be specified, and the results of the operation inspection and the adjustment measures taken should be recorded.
8. Film faced plywood supplier control of substandard products.
The film faced plywood supplier shall establish control procedures for non-conforming products, which shall include non-conforming identification methods, isolation and disposal, and corrective and preventive measures to be taken.
Templates that have been repaired and reworked should be re-tested. Corresponding records should be made for the repair of important parts, and records of the disposal of non-conforming products should be kept.
9. Film faced plywood supplier internal quality audit.
The film faced plywood supplier shall establish a documented internal quality audit procedure to ensure the effectiveness of the quality system and the consistency of the template, and record the results of the internal audit.
Complaints against film faced plywood suppliers, especially for templates that do not meet standards, should be recorded and entered as information for internal quality audits.
Corrective and preventive measures should be taken and recorded for the problems found in the internal audit of film faced plywood supplier.
10. The standardness of film faced plywood.
The film faced plywood supplier shall control the consistency of the mass-produced film faced plywood with the type-checked samples so that the film faced plywood continues to meet the specified requirements.
The film faced plywood supplier shall establish a change control procedure for the film faced plywood key raw materials, construction and other factors that affect the compliance of the formwork with the specified requirements.
Changes to the template (which may affect compliance with relevant standards or consistency with type inspection samples) should be reported to the certification body and approved before implementation.
11. Film faced plywood packaging, handling and storage.
Any packaging, handling operations and storage conditions performed by the film faced plywood supplier shall not affect the formwork’s compliance with the specified standards.